主页 >> 产品 >> KT-N9020B-526
 
其它可用的配置。
请打电话找本公司经验丰富的销售人员。
 
Keysight Technologies (前 Agilent) N9020B-526
10Hz-26.5GHz MXA Signal Analyzer
 
浏览
查看数据表
部件号包括的选项
选择需报价的项目
租用/租赁 买二手设备
KT-N9020B-526 
KT-N9020B-526/EA3/P26/3.6GHz Electronic attenua/26.5GHz Preamplifier
KT-N9020B-526/NF2/Noise floor extension
KT-N9020B-526/NF2/P26/Noise floor extension/26.5GHz Preamplifier
KT-N9020B-526/P26/26.5GHz Preamplifier
KT-N9020B-526/P26/PFR/26.5GHz Preamplifier/Precision frequency refer
KT-N9020B-526/Z1/B1X/EA3/MPB/P26/PFR/RT2
产品目录品名

Keysight Technologies (前 Agilent) N9020B-526

10 Hz to 26.5 GHz MXA Signal Analyzer, Multi-touch


The Keysight N9020B MXA X-Series signal analyzer offers RF, uW and
millimeter frequency ranges for quick, easy performance of diverse noise
measurements such as noise figure, phase noise, and spur search
(sensitivity). With performance that beats the competition, and the largest
suite of measurement applications across technologies and industries,
the MXA is the signal (spectrum) analyzer of choice for RF, uW, millimeter
wave and digital signal analysis.

Optional measurement application software provides preconfigured
test routines for GSM/EDGE, 802.16e Mobile WiMAX, W-CDMA,
HSDPA/HSUPA, and phase-noise applications. Running the 89600
VSA software application in the MXA enables advanced signal
demodulation analysis and troubleshooting of more than 50 demodulation
formats including: 2G, 3G, 3.5G, WiMAX, WLAN and Private Mobile Radio.

         
Features:
Analysis BW 25MHz standard, optional 40, 85, 125, and 160 MHz bandwidths.
Real-Time Bandwidths: 85, 125, and 160 MHz
DANL @ 1 GHz: -166 dBm
Overall Amplitude Accuracy: +/- 0.23 dB
Third Order Intercept @1 GHz (1MHz offset): +20 dBm
Phase Noise (1GHz Center Frequency):
-114 dBc/Hz at 10kHz offset
-114 dBc/Hz at 30kHz offset
-137 dBc/Hz at 1MHz offset
Resolution Bandwidth (RBW):1Hz to 3MHz in (10% steps), 4, 5, 6, 8 MHz
RF input connector: type N (f) 50ohm
2 dB Fine Step Attenuator Standard


Interfaces:
USB 2.0, GPIB, and LAN (100BaseT)
LXI class-C compliant B, Centronics parallel, and 10BaseT.


Rack Mounts:
KT-1CM113A Rack Mount Flange Kit
KT-1CN103A Rack Mount Handle Kit
KT-1CP105A Rack Mount Flange and Handle Kit

See also N9020A MXA Series Signal Analyzer

Hardware Option Descriptions:
B40 40 MHz Analysis bandwidth. DP2 comes with B40 automatically.
Above 3.6GHz, B40 also requires MBP
B85 85 MHz Analysis bandwidth
B1A 125 MHz Analysis bandwidth
B1X 160 MHz Analysis bandwidth
CR3 Wideband IF output connector (Req: DP2 )
CRP Programable rear IF output Connector (Req: B40 or MPB or CR3)
DP2 Digital Processor-2GB Capture Memory
EA3 3.6GHz Electronic attenuator
EDP Enhanced Display Package provides Spectrogram, Trace Zoom, Zone Span
ESC External source control
FSA Fine resolution step attenuator
MBP Microwave preselector bypass requires DP2 or B40
P03 3.6 GHz Preamplifier
P08 8.4 GHz Preamplifier
P13 13.6 GHz Preamplifier
P26 26.5 GHZ Preamplifier
PFR Precision Freq Ref
RT1 Real-Time analysis up to maximum bandwidth, basic detection
RT2 Real-Time analysis up to maximum bandwidth, optimum detection
YAS Y-axis ouptut
N9010B-1DVR01A DVD-ROM/CD-R/RW Drive

Internal Operating System:
Windows 7 Embedded Operating System - Standard

Software descriptions and requirements:
(Available as transportable licenses)
89601B Software compatible
N9063C Analog demodulation measurement application
N9068C Phase Noise Measurement Application
N9069C Noise figure measurement application
N9073C W-CDMA/HSPA+ Measurement Application
N9080C LTE/LTE-Advanced FDD Measurement Application
N9082C LTE/LTE-Advanced TDD Measurement Application


Electro Rent defined bundles:



装运重量 
14.5 " 16.8 " 7 " 62 lb  
    
N/A 目前不出售的二手设备
需要配置方面的协助吗?请打电话找本公司经验丰富的销售人员。